AV-45 PET Scan Information data. More information is available at https://adni.loni.usc.edu/data-samples/adni-data/

Usage

data(AV45META)

Format

A data frame with 3400 observations and 52 variables.

Details

  • ORIGPROT character Original study protocol , with options: ADNI1, ADNIGO, ADNI2

  • COLPROT factor Study protocol of data collection , with levels: ADNI1, ADNIGO, ADNI2, ADNI3, ADNI4

  • ID numeric Range value: 8, ..., 6410

  • PTID character Participant ID

  • RID numeric Participant roster ID Range value: 2, ..., 5296

  • SITEID numeric Site ID Range value: 1, ..., 61

  • VISCODE character Visit code

  • VISCODE2 character Translated visit code

  • USERDATE Date record created Date: YYY-MM-DD

  • USERDATE2 Date record last updated Date: YYY-MM-DD

  • RECNO numeric Range value: 1, ..., 3

  • PMCONDCT character Was the scan conducted? 1=Yes ; 0=No Decoded Value: Yes

  • PMREASON character Reason why the scan was not conducted:

    • ADNIGO: 1=Illness ; 2=Participant unavailable ; 3=Participant unwilling ; 4=Administrative problems ; 5=Withdrawn consent ; 6=Other (specify)

    • ADNI2: 1=Illness ; 2=Participant unavailable ; 3=Participant unwilling ; 4=Administrative problems ; 8=Software/scanner error ; 5=Withdrawn consent ; 7=Not called for by the protocol ; 6=Other (specify)

    Decoded Value: Yes

  • RADTRACER character If no, was radiotracer administered? 1=Yes ; 0=No Decoded Value: Yes

  • EXAMDATE Examination Date Date: YYY-MM-DD

  • PMSCANNER character GE 1=check here Decoded Value: Yes

  • PMGEMODEL character If GE, Scanner Model:

    • ADNIGO: 1=Advance ; 2=Discovery LS ; 3=Discovery ST ; 4=Discovery RX ; 5=Discovery STE/VCT

    • ADNI2: 1=Advance ; 2=Discovery LS ; 3=Discovery ST ; 4=Discovery RX ; 5=Discovery STE/VCT ; 6=Discovery 600 ; 7=Discovery 690

    Decoded Value: Yes

  • PMSIEMENS character Siemens 1=check here Decoded Value: Yes

  • PMSIEMODEL character If Siemens, Scanner Model: 1=ACCEL/EXACT ; 2=Biograph (Model 1023/1024) ; 7=Biograph HiRes (Model 1080) ; 3=BioGraph TruePoint (Model 1093/1094) ; 4=BioGraph mCT ; 5=HR+ ; 6=HRRT Decoded Value: Yes

  • PMPHILLIPS character Phillips 1=check here Decoded Value: Yes

  • PMPHMODEL character If Phillips, Scanner Model: 1=Allegro ; 2=Gemini ; 3=Gemini-GXL ; 4=Gemini-TF Decoded Value: Yes

  • PMQCTIME character Time of today's Scanner QC

  • PMFDGTIME character Time of Florbetapir F18 dose assay

  • PMFDGDOS numeric Florbetapir F18 dose assay Range value: 0.4, ..., 98

  • PMFDGVOL numeric Florbetapir F18 Volume Range value: 0, ..., 97

  • PMINJTIME character Time of Florbetapir F18 injection

  • PMSCTIME character Standard Emission Scan Start Time

  • PMVARIAT character Any variations from protocol during Florbetapir F18 uptake? 1=Yes ; 0=No Decoded Value: Yes

  • PMPROTID character Predefined Acquisition Protocol ID

  • PMFRAME character For the standard late acquisition, which framing rate was used?

    • ADNIGO: 1=4 frames, 5 min/frame (4x300s) ; 2=2 scans, 10 min each (2x600s) (only for BioGraph scanners without list-mode)

    • ADNI2: 1=4 frames, 5 min/frame (4x300s) ; 2=2 scans, 10 min each (2x600s) (only for BioGraph scanners without list-mode) ; 3=1 frame, 20 min (1x1200s) (only for the oldest BioGraph scanners: Models 1023 or 1024)

    Decoded Value: Yes

  • PMDEVIAT character If any deviations, describe:

  • PMMOTION character Subject motion problems: 1=Yes ; 0=No Decoded Value: Yes

  • PMMALFUN character Scanner malfunction 1=Yes ; 0=No Decoded Value: Yes

  • PMOTHER character Other protocol variations: 1=Yes ; 0=No Decoded Value: Yes

  • PMRECON character Check which of the following reconstructions was used:

    • ADNIGO: 2=FORE/2D-OSEM (Siemens) ; 4=OSEM3D (Siemens) (If HHRT scanners using OP, please select OSEM3D) ; 5=3D Iterative (GE) ; 1=3D-Ramla (Philips) ; 3=3D Back-projection (GE)

    • ADNI2: 2=FORE/2D-OSEM (Siemens) ; 4=OSEM3D (Siemens) (If HHRT scanners using OP, please select OSEM3D) ; 5=3D Iterative (GE) ; 6=FORE Iterative (GE) ; 1=3D or LOR Ramla (Philips) ; 3=3D Back-projection (GE)

    Decoded Value: Yes

  • PMSUBSET character # subsets:

    • ADNIGO: 14=14 ; 16=16 ; 20=20 ; 99=Other

    • ADNI2: 12=12 ; 14=14 ; 16=16 ; 20=20 ; 21=21 ; 24=24 ; 32=32 ; 99=Other

    Decoded Value: Yes

  • PMSUBSPE numeric If Other, specify: Range value: 12, ..., 32

  • PMITERAT character # iterations: 4=4 ; 6=6 ; 99=Other Decoded Value: Yes

  • PMITERSPE numeric If Other, specify: Range value: 2, ..., 2

  • PMRAMLA numeric If 3D or LOR Ramla, Lambda= Range value: 0.008, ..., 1

  • PMSHARP character Was 'Smooth' parameter set to 'Sharp'? 1=Check here to confirm Decoded Value: Yes

  • PMFILTER character If 3D Back-Projection, Ramp filter? 1=Check here to confirm Decoded Value: Yes

  • PMMODEON character If FORE/2D-OSEM select one of the following:

    • ADNIGO: 1=Brain Mode "ON" for PET-only Siemens scanners ; 2=TRIM "ON" for PET/CT Siemens scanners (older software versions) ; 3=TRIM not available for PET/CT scanners (new software versions)

    • ADNI2: 1=Brain Mode 'ON' for PET-only Siemens scanners ; 2=TRIM 'ON' for PET/CT Siemens scanners (older software versions) ; 3=TRIM not available for PET/CT scanners (new software versions)

    Decoded Value: Yes

  • PMSMOOTH character No post-process smoothing: 1=Check here to confirm Decoded Value: Yes

  • PMATTEN character Attenuation Correction: 1=CT ; 2=Ge-68+Segmentation ; 3=Cs-137+Segmentation Decoded Value: Yes

  • PMTRNSFR character Was data transferred to LONI within 24 hours of scan? 1=Yes ; 0=No Decoded Value: Yes

  • PMTRNDATE character Transfer Date

  • PMTRNDATEYR_DRVD numeric Transfer Year (Derived from PMTRNDATE) Range value: 2001, ..., 2017

  • PMARCHIVE character Was all raw PET data archived locally to be able to do complete reconstruction of PET Scan if needed? 1=Yes ; 0=No Decoded Value: Yes

  • PMLPDONE character Was a Lumbar Puncture completed prior to the Florbetapir F18 scan? 1=Yes ; 0=No Decoded Value: Yes

  • PMLPINTER character If Yes, What was the interval between LP and Florbetapir F18? 1=less than 6 hours ; 2=6-12 hours ; 3=13-24 hours ; 4=25-48 hours ; 5=49-72 hours ; 6=more than 72 hours Decoded Value: Yes

  • update_stamp POSIXct: YYY-MM-DD