
ADSP Phenotype Harmonization Consortium (PHC) - Composite PET Amyloid Simple Scores
Source:R/data.R
ADSP_PHC_PET_Amyloid_Simple.RdADSP Phenotype Harmonization Consortium (PHC) - Composite PET Amyloid Simple Scores data. More information is available at https://adni.loni.usc.edu/data-samples/adni-data/
Usage
data(ADSP_PHC_PET_Amyloid_Simple)Details
ORIGPROT character Original study protocol , with options: ADNI4, ADNI1, ADNIGO, ADNI2, ADNI3
COLPROT character Study protocol of data collection , with options: ADNI4, ADNI1, ADNI2, ADNIGO, ADNI3
RID numeric Participant roster ID
PTID character Participant ID
SUBJID character Subject ID used in NIAGADS for the whole genome sequencing data files generated by the AD Sequencing Project.
VISCODE character Visit code
VISCODE2 character Translated visit code
PHC_LONIUID numeric LONI Image ID Range value: 75199, ..., 11394049
PHC_SCANDATE Date of scan Date: YYYY-MM-DD
PHC_Visit numeric Harmonized visit number Range value: 1, ..., 20
PHC_Age_PET numeric Participant's Age at PET Data Collection Range value: 50.7186858316222, ..., 98.0752908966461
PHC_TRACER character PET Radiotracer , with options: FBB, FBP, PIB, NAV
PHC_ACQUISITION_START numeric Acquisition start-stop time post-injection (minutes) Range value: 50, ..., 90
PHC_ACQUISITION_END numeric Acquisition start-stop time post-injection (minutes) Range value: 70, ..., 110
PHC_ACQUISITION_TIME numeric Acquisition start-stop time post-injection 1 = 30-60 ; 2 = 40-60 ; 3 = 40-70 ; 4 = 45-75 ; 5 = 45-90 ; 6 = 50-70 ; 7 = 60-90 ; 8 = 70-90 ; 9 = 70-110 ; 10 = 80-100 ; 11 = 90-110 ; 12 = 30-45 ; 99 = outside of acceptable range
PHC_QC_IMAGE numeric Determination if scan passed or failed quality control– image quality 0 = Fail ; 1 = Pass ; 2 = Pending
PHC_QC_TIMING numeric Determination if scan passed or failed quality control– acquisition time 0 = Fail ; 1 = Pass ; 2 = Pending
PHC_QC_NOTES numeric Notes related to failed quality control. 1 = Abnormal image ; 2 = Technical problem ; 3 = Anatomic abnormality ; 4 = Bottom of brain cut ; 5 = Early finish ; 6 = Early start ; 7 = Front of brain cut ; 8 = High glucose ; 9 = Late start ; 10 = Motion-induced attenuation artifact ; 11 = No attenuation or scatter correction ; 12 = Scan aborted early ; 13 = Severe motion ; 14 = Top of brain cut ; 15 = Wrong reconstruction parameters (16) Wrong voxel size ; 88 = Pass/Pending ; 99 = Other
PHC_COMPLIANT_ACQUISITION_START numeric Tracer compliant acquisition start time post-injection (minutes) Range value: 50, ..., 90
PHC_COMPLIANT_ACQUISITION_END numeric Tracer compliant acquisition stop time post-injection (minutes) Range value: 70, ..., 110
PHC_INJECTED_DOSE numeric Measure of injected radioligand dose (millicurie) Range value: 8.1, ..., 15
PHC_DYNAMIC numeric Whether dynamic (multiple frames available) or static 1 = static ; 2 = dynamic
PHC_CENTILOIDS numeric Centiloids (CLs) values converted from GAAIN summary cortical SUVR normalized by GAAIN whole cerebellum; See ADSP MRI-Free PET Methods document Range value: -63, ..., 194
PHC_AMYLOID_STATUS numeric Amyloid positivity determined by applying thresholds to the GAAIN summary cortical SUVR normalized by GAAIN whole cerebellum; See ADSP MRI-Free PET Methods document 0 = negative ; 1 = positive ; 9 = unknown
PHC_CL_FAIL logical Projected centiloid values for images that failed QC_TIMING A Boolean value: TRUE/ FALSE
update_stamp POSIXct: YYYY-MM-DD HH:MM:SS