ADSP Phenotype Harmonization Consortium (PHC) - Composite FLAIR Scores
Source:R/data.R
ADSP_PHC_FLAIR.RdADSP Phenotype Harmonization Consortium (PHC) - Composite FLAIR Scores data. More information is available at https://adni.loni.usc.edu/data-samples/adni-data/
Usage
data(ADSP_PHC_FLAIR)Details
ORIGPROT character Original study protocol , with options: ADNI4, ADNI1, ADNIGO, ADNI2, ADNI3
COLPROT character Study protocol of data collection , with options: ADNI4, ADNI2, ADNI3, ADNI1, ADNIGO
RID numeric Participant roster ID
PTID character Participant ID
SUBJID character Subject ID used in NIAGADS for the whole genome sequencing data files generated by the AD Sequencing Project.
VISCODE character Visit code
VISCODE2 character Translated visit code
PHC_LONIUID numeric LONI Image ID Range value: 35254, ..., 11433158
PHC_SCANDATE Date of scan Date: YYYY-MM-DD
PHC_Visit numeric Harmonized visit number Range value: 1, ..., 20
Imaging_Site numeric Location Site of Imaging Scan Range value: 2, ..., 941
PHC_Age_FLAIR numeric Age at each FLAIR visit Range value: 50.5325119780972, ..., 97.45106091718
FieldStrength numeric Strength of the magnetic field used in the MRI scanner, measured in Tesla. Range value: 1.5, ..., 3
Manufacturer character Manufacturer of the MRI scanner , with options: Siemens Healthineers, SIEMENS, Philips, GE MEDICAL SYSTEMS, Philips Medical Systems, Philips Healthcare, Siemens
Model character The specific model name of the MRI scanner, usually provided by the manufacturer.
Image_Dimensions_vox character Dimensions of the acquired FLAIR image
SliceThickness numeric Thickness of each individual slice or section in the FLAIR image, measured in millimeters Range value: 0.999145, ..., 15.000004
EchoTime numeric Time between the center of the excitation pulse and the center of the echo, measured in milliseconds. Range value: 0.000101923, ..., 0.445
RepetitionTime numeric Time between successive MRI pulse sequences, measured in milliseconds. Range value: 0, ..., 12
FlipAngle numeric Angle between the net magnetization vector and the magnetic field, usually determined by the MRI pulse sequence. Range value: 9, ..., 180
CNR_WM numeric Contrast-to-noise ratio for total white matter Range value: 2.762, ..., 4.706
SNR_WM numeric Signal-to-noise ratio for total white matter Range value: 2.848, ..., 4.964
CNR_GM numeric Contrast-to-noise ratio for total gray matter Range value: 2.663, ..., 4.522
SNR_GM numeric Signal-to-noise ratio for total gray matter Range value: 2.998, ..., 4.814
Contrast_WM_GM numeric Measure of the contrast difference between white matter and gray matter in the MRI scan. Range value: 0, ..., 1.623
PHC_WMHVOL_Harmonized numeric Total volume of white matter hyperintensities (WMH) in the brain, measured in cubic centimeters harmonized across studies using standard Combat method Range value: 0.00095041499869275, ..., 137.042170176941
update_stamp POSIXct: YYYY-MM-DD HH:MM:SS